PMOS Digital Alarm Clock
Features:
- Single-Chip ED MOS LSI
- LED Direct Drive by Time-Sharing (Duplex)
- Wide Operating Voltage Range
- Alarm on a 24-Hour Basis
- Two Selections of Time Format:
AM/PM 12-Hour Basis & 24-Hour Basis
- On-Chip CR Oscillator for Battery Backup
- 50Hz or 60Hz Reference Frequency
- Automatic Advance Capable:
“Hours”, “Minutes”
- Sleep Timer:
Max. 59 Minutes or 1Hour, 59 Minutes
- Repeatedly Usable Snooze
- Power Failure Indicator
- 900Hz Output for Alarm Tone
Functions:
- Real Time Display
- Alarm with Snooze
- Sleep Timer
Applications:
- Alarm Clock
- Clock Radio
Info as pdf-file
NTE-ECG replacement list as pdf-file
NTE-ECG diagrams
Absolute Maximum Ratings: (VSS = 0, TA = +25°C unless otherwise specified)
Maximum Supply Voltage, VDDmax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Input Voltage, VIN
50/60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Other Than 50/60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Output Voltage, VOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Input Clamp Current, IIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.4 to +0.4mA
Allowable Power Dissipation (TA = +70°C), PDmax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700mW
Operating Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30° to +70°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55° to +125°C
Operation Description:
50Hz/60Hz Input:
The On-Chip Schmitt Trigger circuit allows a simple RC filter at the input to remove possible line voltage
transients. An internal pull-up resistor is provided.
CR Input: (Note 1)
When AC power-down occurs, the time counter enters the “hold” mode and the on-chip clock oscillator
starts operating immediately. If there is no input at “50/60Hz input” during 3-clock period, this oscillator
controls the time counter advance instead of “50/60Hz input”. The values of CR determine the
frequency of the on-chip clock oscillator. All segment outputs are off during backup operation. If the
backup OSC is used at the power-down mode, “50/60Hz input” must be open or at VSS level.
50/60Hz Select Input:
Connecting “50/60Hz select” to VSS enables 50Hz operation. For 60Hz operating, “50/60Hz select”
is left unconnected: Pull-down to VDD is provided by the internal pull-down resistor.
Display Mode Select Input (Alarm Display/Sleep Display):
The internal pull-down resistor allows the use of 2 SPST (single-pole single-throw) switches to select
4 display modes listed in
Table 1.
Time Setting Input:
Two setting inputs for ´Hours´ and ´Minutes´ are provided. The application of VSS causes the time setting
in Table 2 to occur. An internal pull-down resistor each is provided.
Note 2. When “Seconds” display is at 50 to 59, “Seconds” are reset to [00] and a carry occurs to increment
“Minutes” +1.
Note 3. Once the reset mode or hold mode is entered, another function is locked until both “Hour Set”
input and “Minute Set” inputs are released.
12/24-Hour Select Input:
Leaving this pin unconnected (VDD) causes the 12-Hour basis to be selected; connecting this pin
to VSS causes the 24-Hour basis to be selected. An internal pull-down resistor is provided.
Power Failure Indicator:
If the power supply voltage drops and is applied again, all the on-segments flash and the power failure
indication mode is entered. The power failure indication mode is released by applying VSS to “Hour
Set” or “Minute Set”.
Alarm Operation and Alarm Output:
When the alarm set time is reached, the alarm signal is delivered. This signal continues to be delivered
for 1 hour 59 minutes unless reset by “Alarm Off” or “Snooze Input”. This signal is provided for
the tone-signal of 900Hz with 50% duty of 2Hz gated. A simple LPF can be used to turn this alarm
signal into DC signal as required.
Snooze Input:
By momentarily connecting this pin to VSS at the alarm on-state, the alarm output is inhibited for 8
to 9 minutes, after which the alarm signal is delivered again. The snooze function can be used repeatedly
for 1 hour 59 minutes. An internal pull-down resistor is provided. By connecting “Snooze Input”
to VSS at the alarm off-state, the sleep timer counter is reset to [0:00]. (The sleep timer is reset with
one touch).
Alarm Off Input:
Connecting this input pin to VSS inhibits the alarm output momentarily. An internal pull-down resistor
is provided.
Sleep Timer and Sleep Output:
The sleep output can be used to keep the radio turned on for any period of time up to 59 minutes or
1 hour 59 minutes. Table 2 shows how to select the period (59 minutes or 1 hour 59 minutes). This
sleep timer uses a down counter. When the counter contents reach [00], the output stops being delivered,
turning off the radio. By connecting “Snooze Input” to VSS at the sleep output on-state, the sleep
output is inhibited.
Unser Halbleiter Katalog (ohne NTE-Sortiment)
NTE Sortiment (unser ganzes Sortiment)
Einzel-Halbleiter (ganzes Sortiment)
Fehler und Änderungen bei technischen Daten, Abmessungen und Preisen bleiben vorbehalten. Bild kann vom Original abweichen.
Hat sich ein Fehler eingeschlichen?
Bitte hier melden
Suchen Sie nach einem Ersatztypen?
Anmerkung zu den NTE/ECG Austauschhalbleiter:
NTE-Austauschhalbleiter (früher ECG Philips und Sylvania) sind sorgfältig
ausgesuchte und erprobte Halbleiter, die einen sicheren Ersatz
für Originaltypen verschiedenster Hersteller und Ursprünge für
fast alle Applikationsbereiche im Wartungsdienst bieten.
Alle NTE-Austausch-Halbleiter sind einzeln in durchsichtigen
Plastikbeuteln verpackt, auf welchen die wichtigsten Daten
vermerkt sind.