9.50CHF
ab 10 8.55CHF
ab 50 8.01CHF
ab 100 7.55CHF

NTE2062 IC PMOS Digital Alarm Clock DIP-28

Bestell-Nr.:    NTE2062


Verfügbarkeit:     PICTURE_ONLY_ONE
  Sofort lieferbar!


NTE2062 NTE-2062 | ECG2062 ECG-2062 | NTE Electronics NTE2062
Integrated Circuit PMOS Digital Alarm Clock

Features:
- Single-Chip ED MOS LSI
- LED Direct Drive by Time-Sharing (Duplex)
- Wide Operating Voltage Range
- Alarm on a 24-Hour Basis
- Two Selections of Time Format: AM/PM 12-Hour Basis & 24-Hour Basis
- On-Chip CR Oscillator for Battery Backup
- 50Hz or 60Hz Reference Frequency
- Automatic Advance Capable: “Hours”, “Minutes”
- Sleep Timer: Max. 59 Minutes or 1Hour, 59 Minutes
- Repeatedly Usable Snooze
- Power Failure Indicator
- 900Hz Output for Alarm Tone

Functions:
- Real Time Display
- Alarm with Snooze
- Sleep Timer

Applications:
- Alarm Clock
- Clock Radio

Info as pdf-file
NTE-ECG replacement list as pdf-file
NTE-ECG diagrams

Absolute Maximum Ratings: (VSS = 0, TA = +25°C unless otherwise specified)
Maximum Supply Voltage, VDDmax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Input Voltage, VIN
50/60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Other Than 50/60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Output Voltage, VOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -15 to +0.3V
Input Clamp Current, IIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.4 to +0.4mA
Allowable Power Dissipation (TA = +70°C), PDmax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700mW
Operating Temperature Range, Topr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30° to +70°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55° to +125°C

Operation Description:
50Hz/60Hz Input:
The On-Chip Schmitt Trigger circuit allows a simple RC filter at the input to remove possible line voltage transients. An internal pull-up resistor is provided.
CR Input: (Note 1)
When AC power-down occurs, the time counter enters the “hold” mode and the on-chip clock oscillator starts operating immediately. If there is no input at “50/60Hz input” during 3-clock period, this oscillator controls the time counter advance instead of “50/60Hz input”. The values of CR determine the frequency of the on-chip clock oscillator. All segment outputs are off during backup operation. If the backup OSC is used at the power-down mode, “50/60Hz input” must be open or at VSS level.
50/60Hz Select Input:
Connecting “50/60Hz select” to VSS enables 50Hz operation. For 60Hz operating, “50/60Hz select” is left unconnected: Pull-down to VDD is provided by the internal pull-down resistor.
Display Mode Select Input (Alarm Display/Sleep Display):
The internal pull-down resistor allows the use of 2 SPST (single-pole single-throw) switches to select 4 display modes listed in
Table 1.

Time Setting Input:
Two setting inputs for ´Hours´ and ´Minutes´ are provided. The application of VSS causes the time setting in Table 2 to occur. An internal pull-down resistor each is provided.

Note 2. When “Seconds” display is at 50 to 59, “Seconds” are reset to [00] and a carry occurs to increment “Minutes” +1.
Note 3. Once the reset mode or hold mode is entered, another function is locked until both “Hour Set” input and “Minute Set” inputs are released.
12/24-Hour Select Input:
Leaving this pin unconnected (VDD) causes the 12-Hour basis to be selected; connecting this pin to VSS causes the 24-Hour basis to be selected. An internal pull-down resistor is provided.
Power Failure Indicator:
If the power supply voltage drops and is applied again, all the on-segments flash and the power failure indication mode is entered. The power failure indication mode is released by applying VSS to “Hour Set” or “Minute Set”.
Alarm Operation and Alarm Output:
When the alarm set time is reached, the alarm signal is delivered. This signal continues to be delivered for 1 hour 59 minutes unless reset by “Alarm Off” or “Snooze Input”. This signal is provided for the tone-signal of 900Hz with 50% duty of 2Hz gated. A simple LPF can be used to turn this alarm signal into DC signal as required.
Snooze Input:
By momentarily connecting this pin to VSS at the alarm on-state, the alarm output is inhibited for 8 to 9 minutes, after which the alarm signal is delivered again. The snooze function can be used repeatedly for 1 hour 59 minutes. An internal pull-down resistor is provided. By connecting “Snooze Input” to VSS at the alarm off-state, the sleep timer counter is reset to [0:00]. (The sleep timer is reset with one touch).

Alarm Off Input:
Connecting this input pin to VSS inhibits the alarm output momentarily. An internal pull-down resistor is provided.
Sleep Timer and Sleep Output:
The sleep output can be used to keep the radio turned on for any period of time up to 59 minutes or 1 hour 59 minutes. Table 2 shows how to select the period (59 minutes or 1 hour 59 minutes). This sleep timer uses a down counter. When the counter contents reach [00], the output stops being delivered, turning off the radio. By connecting “Snooze Input” to VSS at the sleep output on-state, the sleep output is inhibited.


Unser Halbleiter Katalog (ohne NTE-Sortiment)
NTE Sortiment (unser ganzes Sortiment)
Einzel-Halbleiter (ganzes Sortiment)

Fehler und Änderungen bei technischen Daten, Abmessungen und Preisen bleiben vorbehalten. Bild kann vom Original abweichen.
Hat sich ein Fehler eingeschlichen? Bitte hier melden


Suchen Sie nach einem Ersatztypen?

Anmerkung zu den NTE/ECG Austauschhalbleiter:
NTE-Austauschhalbleiter (früher ECG Philips und Sylvania) sind sorgfältig ausgesuchte und erprobte Halbleiter, die einen sicheren Ersatz für Originaltypen verschiedenster Hersteller und Ursprünge für fast alle Applikationsbereiche im Wartungsdienst bieten.
Alle NTE-Austausch-Halbleiter sind einzeln in durchsichtigen Plastikbeuteln verpackt, auf welchen die wichtigsten Daten vermerkt sind.
Anzahl:
Bewertungen

Kunden, die dieses Produkt gekauft haben, haben auch folgende Produkte gekauft:
Schnellsuche
0 Waren
Hersteller
Hersteller Info
andere Produkte
Sprachen
English Deutsch
Währungen